.delivery-table { width: 100%; border-collapse: collapse; margin-top: 10px; table-layout: fixed; } .delivery-table th, .delivery-table td { border: 1px solid #333; padding: 10px; text-align: left; vertical-align: top; font-size: 14px; } .delivery-table th { background-color: #f5f5f5; font-weight: bold; } /* Smaller zone column */ .zone { width: 70px; font-weight: bold; text-align: left; } /* Give more room to states */ .states { width: auto; } /* Subtle separation between zones */ .delivery-table tr.zone-divider td { border-top: 2px solid #333; } Zone States 1 Arizona, California, Idaho, Nevada, Oregon, Utah, Washington, Montana, New Mexico, Wyoming, Colorado 2 Georgia, Alabama, Mississippi, Tennessee, Kentucky, Florida, South Carolina, North Carolina, Ohio, Indiana, Illinois, Michigan, Wisconsin, West Virginia, Virginia, Pennsylvania, Maryland, Delaware, New Jersey, Connecticut, Massachusetts, Rhode Island, Maine, New Hampshire, Vermont, New York 3 Louisiana, Texas, Oklahoma, Missouri, Minnesota, North Dakota, South Dakota, Nebraska, Kansas, Arkansas, Iowa Rmax ECOMAXci® FR Air Barrier is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam core bonded to glass fiber reinforced aluminum foil facers on both sides. Glass fiber reinforcement on both faces of the board offer enhanced durability, dimensional stability, and fire performance. The printed side, exposed to the exterior, has a robust embossed 12mil facer with an aluminum reflective surface and clear coating for limited protection against oxidation ensuring Jobsite security and enhanced radiant heat protection. Thickness Sq/Ft Per Pallet Sheets Per Pallet Minimum Order 0.75" 1920 60 6 Pallets 1" 1334 42 6 Pallets 1.5" 960 30 6 Pallets 2" 768 24 6 Pallets 2.5" 608 19 6 Pallets 3" 512 16 6 Pallets 3.5" 416 13 6 Pallets COMPLIANCES ASTM C1289 Type I, Class 1 and 2 ASHRAE 90.1 International Energy Conservation Code (IECC) International Building Code (IBC) Section 2603, Foam Plastic DrJ TER 1212-03 • CA Insulation Directory Tested per NFPA 285 to comply with IBC Section 2603.5.5 Class A Flame Spread and Smoke Developed Indices per IBC Chapter 8, Interior Finishes Approved component for use within the ECOMAXci™ Wall Solution Water-Resistive Barrier (WRB) Component per ICC-ES AC71 (ASTM E331, AATCC Test Method 127) Air Barrier System Component ASTM E2357, CAN/ULC-S742 (A1) High-Velocity Hurricane Zone system, R-Trac (HVHZ) Florida Building Code Approval #FL16406 Tested per TAS 201,202 and 203 Tested per ASTM E1886 and E1996 1, 2, 3 or 4 hour Fire Rated Assemblies as shown in the UL Fire Resistance Directory APPLICATIONS Exterior walls (Type I-IV): masonry walls; steel stud walls
Checkout happens on the official store. This page mirrors catalog facts in plain HTML for direct reading and crawlability.